EMISSION CONTROL INFORMATION 11-7 • Connect the 12 V battery to the PAIR control solenoid valve terminals and check the air flow. • If air does not flow out, the solenoid valve is in normal condi- tion. 12V • Check the resistance between the terminals of the PAIR con- trol solenoid valve. Resistance: 18 – 22 Ω at 20 – 30 °C (68 – 86 °F) 09900-25008: Multi-circuit tester set Tester knob indication: Resistance (Ω) INSTALLATION E If the resistance is not within the standard range, replace the PAIR control solenoid valve with a new one. L Installation is in the reverse order of removal. P • Connect the PAIR control solenoid valve lead wire coupler and PAIR hoses securely. AM S