EXHAUST SYSTEM 6-13 If the measured voltage is more than specification, adjust the No.2 cable adjuster as follows: • Set the EXCVA to adjustment position. (6-4)  Adjusting the No. 2 cable with the EXCV fully opened can damage the EXCVA. Be sure to adjust the No. 2 cable with the EXCV set in adjustment position. • Turn out the No. 2 cable adjuster 1. • Repeat the above procedure until the output voltage comes within the specified value. Position sensor output voltage EXCV is fully open: 3.7 output voltage 4.5 V • After adjusting the EXCV cables, perform 2nd step to confirm C46 is not indicated. EXCV/MUFFLER REMOVAL • Disconnect the two cables from the EXCVA pulley. (Refer to E the EXCVA REMOVAL procedures.) (6-4 to -5) • Remove the right under cowling. (8-5) L • Move the front footrest assembly. (8-5) P • Remove the cable guide. M A • Loosen the connector bolt 1. S • Remove the muffler mounting bolts 2. • Remove the muffler body 3.

Suzuki GSXR 1000 K5 K6 - Page 299 Suzuki GSXR 1000 K5 K6 Page 298 Page 300